X

Building Management & Security System Cables

  • Filters

Access Control System Composite Cables

Specification
UNIT 1 - 4 CORE X 18 AWG, UNIT 2 - 3 PAIR X 22 AWG, UNIT 3 - 2 CORE X 22 AWG & UNIT 4 - 4 CORE X 22 AWG
Stranded (Class-2) Annealed bare copper conductor, Polypropylene (PP) insulated, 3 Un-shielded & Low-Smoke PVC jacket over Units (i.e. 4CX18 AWG, 2CX22 AWG & 4CX22 AWG) & 1 Shielded & Low-Smoke PVC Jacket over Unit (i.e. 3PX22 AWG) laid up concentrically and overall FR-LSH Jacketed Composite Access Control Cable.
Application
 Access Control Systems: The cable is clearly labeled and designed for access control systems. The marked conductors called out use cases like "Lock Power", "Card Reader", "Door Contact" (Diagram given below) etc. So it's intended to consolidate cables needed for a full access control installation.

Price upon request

Co-Axial & CCTV Cables

Specification
RG6, RG11 and RG59 (CCTV)
Cable Type: Cable Type: Un-Armoured
Shielding Type: Foil and Aluminium-Alloy Brading
Application
 Cable TV Distribution
 Satellite TV Reception and Distribution
 Broadband Internet Access
 CCTV Systems
 Home Theater Installations
 Residential Cell Phone Signal Boosters,
 Broadband Video Distribution
 Commercial Building Wiring
 Industrial Applications
 Outdoor Antenna Connections
 Radio Antennas, and Digital Cable
 Satellite Receivers

Price upon request

DMX Lighting Control Cables


Specification
22 AWG (1 Pair & 2 Pair)
Stranded (Class-2) Annealed Tinned Copper Conductor, Polyolefin Insulated, Twisted pairs laid-up, Overall shielded (100% Coverage) with Aluminium Mylar tape, ATC drain wire & Annealed tinned copper wire Braid (80% Coverage) and Overall PVC Jacketed DMX Lighting Control Cables.
Generally as per IS:694 & IEC:60228
Application
 DMX cables are commonly used in a variety of professional lighting and control applications, including:
 Stage Lighting
 Studio lighting setups
 Architectural Lighting
 Nightclubs and Entertainment Venues
 Film and Television Production
 Architectural Installations

Price upon request

Microphone Audio Cable

Specification
22 AWG (1 Pair & 2 Pair)
Flexible (Class-5) Annealed Bare Copper Conductor, Polyolefin Insulated, Cores laid-up concentrically, Cotton filler, Overall Spiral shielded (100% Coverage) with Annealed Bare Copper Wires and Overall Special PVC Jacketed Microphone Audio Cable.
Application
 Recording Studios
 Live sound setups
 Theater and Performance
 Conference and Meeting Rooms
 Professional audio & broadcast
 Suitable for High-quality audio signal transmission application

Price upon request

LAN Cable

Specification
4P x 23 AWG / 24 AWG
Cable Type: CAT 5e, CAT 6, CAT 6A, CAT 7, CAT 7A 
Shielding Type: UTP, FTP, STP, SFTP, F/FTP, S/FTP, SF/FTP
Jacketing Type: FR PVC, FR-LSH PVC and LSZH
Application
 Computers
 Routers, Modems, & Printers 
  VoIP Phones and IP Cameras
 Smart Home Devices and Smart TVs 
 Industrial Networking Equipment
 Audio/Video Devices
 Network Attached Storage (NAS) Devices

Price upon request

Speaker Cables

Application
  Emergency Notification 
 Outdoor Sound Systems
 Commercial and Retail Installations 
  Entertainment Venues like auditoriums, theaters and conference rooms

Price upon request

RS-485 Communication Cable (Low Capacitance)

Specification
24 AWG to 16 AWG (1 Pair to 4 Pair)

Stranded (Class-2) Annealed Tinned Copper Conductor, Polyolefin Insulated, Twisted pairs laid-up, Overall shielded (100% Coverage) with Aluminium Mylar tape, ATC drain wire & Annealed tinned copper wire Braid (80% Coverage) and Overall FR-LSH Jacketed RS-485 Communication cable.
Reference standards:Generally as per BS EN 50288-7, IEC:60228 & IEC:60332-1-2
Application
 Communication between various heating, ventilation, and air conditioning components in commercial and industrial HVAC systems, enabling centralized control and monitoring
 Access control panels, card readers, and peripherals, ensuring reliable communication in secure access environments.
 Connecting PLCs, sensors, and control devices in industrial automation systems
 Environmental monitoring and process control applications
 Long-distance communication where noise immunity are essential

Price upon request

Fire Survival Armoured Cable IS:17505-1 (XLPE Insulation)

1.50 Sqmm to 400 Sqmm (2 Core, 3 Core & 4 Core)
25 Sqmm to 400 Sqmm (3.5 Core)
1.5 Sqmm to 2.5 Sqmm ( 5 Core to 61 Core)
Stranded (Class-2) Annealed Bare Copper Conductor, Double layer of Glass mica tape wrapped over conductor, XLPE Insulated, Cores laid-up concentrically, LSZH Inner Jacket, GI Wire Armoured and Overall LSZH Jacketed Fire Survival Armoured Cables. 
Fire survival test : 950 Deg.C for 3 Hours, FWS Category
Reference standards: IS: 17505-1 
Certification: BIS Certified & ISI Mark
Application
 Fire Alarm Systems
 Public Address Systems
 Fire Pumps, Pressurization Systems
 Emergency Lighting Exit Signage Lighting
 Smoke Ventilation ( Dampers & Actuators )
 Fire Fighting Shafts (Staircase, Lift, Lift Lobby)
 Magnetic Door Hold Open Devices
 Fireman’s Lifts
 Lighting in Fire
 Command Centers & Security Rooms
 And Other Critical Applications

Price upon request

Fire Survival Shielded Un-Armoured Cables BS:7629-1

Specification
0.75 Sqmm & 2.50 Sqmm (2 Core & 4 Core)

Stranded Annealed Bare Copper Conductor, Double layer of Glass mica tape wrapped over conductor, XLPE Insulated, Cores Laid-up, Overall shielded(100% Coverage) with Aluminium Mylar tape in contact with ATC Drain wire and Overall LSZH Jacketed Un-Armoured Fire Survival Shielded Cables.
Fire survival test : FS test as per BS EN:50200 PH30.
Reference standards : BS:7629-1 & IEC:60228
Application
 Fire Alarm Systems
 Public Address Systems
 Fire Pumps, Pressurization Systems
 Emergency Lighting Exit Signage Lighting
 Smoke Ventilation ( Dampers & Actuators )
 Fire Fighting Shafts (Staircase, Lift, Lift Lobby)
 Magnetic Door Hold Open Devices
 Fireman’s Lifts
 Lighting in Fire
 Command Centers & Security Rooms
 And Other Critical Applications

Price upon request

Fire Survival Armoured Cable BS:7846 (XLPE Insulation)

Specification
1.50 Sqmm to 400 Sqmm (2 Core, 3 Core & 4 Core)
1.5 Sqmm to 2.5 Sqmm ( 5 Core to 37 Core)
Stranded (Class-2) Annealed Bare Copper Conductor, Double Layer of Glass mica tape wrapped over conductor, XLPE Insulated, Cores laid-up concentrically, LSZH Inner Jacket, GI Wire Armoured and Overall LSZH Jacketed Fire Survival Armoured Cables.
Fire survival test : 950 Deg.C for 3 Hours, CWZ Category
Reference standards : BS:7846, IEC:60228, BS:6387
Application
 Fire Alarm Systems
 Public Address Systems
 Fire Pumps, Pressurization Systems
 Emergency Lighting Exit Signage Lighting
 Smoke Ventilation ( Dampers & Actuators )
 Fire Fighting Shafts (Staircase, Lift, Lift Lobby)
 Magnetic Door Hold Open Devices
 Fireman’s Lifts
 Lighting in Fire
 Command Centers & Security Rooms
 And Other Critical Applications

Price upon request

Fire Survival Shielded SFR Cables BS:7629-1

Specification
0.75 Sqmm & 2.50 Sqmm (2 Core & 4 Core)

Stranded Annealed Bare Copper Conductor, Ceramified Silicone rubber Insulated, Cores Laid-up, Overall shielded(100% Coverage) with Aluminium Mylar tape in contact with ATC Drain wire and Overall LSZH Jacketed Un-Armoured Fire Survival Shielded SFR Cables.
Fire survival test:FS test as per BS EN:50200 PH30.
Reference standards:BS:7629-1 & IEC:60228
Application
 Fire Alarm Systems
 Public Address Systems
 Fire Pumps, Pressurization Systems
 Emergency Lighting Exit Signage Lighting
 Smoke Ventilation ( Dampers & Actuators )
 Fire Fighting Shafts (Staircase, Lift, Lift Lobby)
 Magnetic Door Hold Open Devices
 Fireman’s Lifts
 Lighting in Fire
 Command Centers & Security Rooms
 And Other Critical Applications

Price upon request

RS-485 Communication Armoured Cable (Low Capacitance)

Specification
24 AWG to 16 AWG (1 Pair to 4 Pair)

Stranded (Class-2) Annealed Tinned Copper Conductor, Polyolefin Insulated, Twisted pairs laid-up, Overall shielded (100% Coverage) with Aluminium Mylar tape, ATC drain wire & Annealed tinned copper wire braid (70% Coverage), PVC Inner Jacket, Galvanized Steel Wire Armoured and Overall FR-LSH Jacketed RS-485 Communication Armoured Cable.
Reference standards:Generally as per BS EN 50288-7, IEC:60228 & IEC:60332-1-2
Application
 Communication between various heating, ventilation, and air conditioning components in commercial and industrial HVAC systems, enabling centralized control and monitoring.
 Access control panels, card readers, and peripherals, ensuring reliable communication in secure access environments.
 Connecting PLCs, sensors, and control devices in industrial automation systems,
 Environmental monitoring and process control applications
 Long-distance communication where noise immunity are essential

Price upon request

Multicore Shielded BMS Cable

Specification
0.50 Sqmm to 2.50 Sqmm ( 2 Core to 12 Core )
Flexible (Class-5) Annealed Tinned / Bare Copper Conductor, HFFR Polypropylene / PVC Insulated, Cores laid-up concentrically, Overall shielded (100% Coverage) with Aluminium Mylar tape in contact with Annealed Tinned Copper Drain wire and Overall HR FR-LSH Jacketed Shielded BMS Cables.
Generally as per BS EN 50288-7, IEC:60228 & IEC:60332-1-2
Application
 Security systems
 Burglar alarm
 Intercom / PA-System
 Cabinet / Panel wiring
 Power limited circuits
 Voice communications / Noisy Environment
 Control/Instrumentation digital signals
 Suitable for low voltage application - Up to 500V system

Price upon request

Multi-Pair Shielded Armoured BMS Cable

Specification
 0.50 Sqmm to 1.50 Sqmm (1 Pair to 12 Pair)
Flexible / Stranded Annealed Bare / Tinned Copper Conductor, PVC Insulated, twisted pair laid-up concentrically, Overall shielded (100% Coverage) with Aluminium Mylar tape in contact with Annealed Tinned Copper Drain wire, PVC Inner Jacket, Galvanized Steel Wire/Strip Armoured and Overall HR FR-LSH Jacketed Shielded Armoured BMS Cable.
Generally as per BS EN:50288-7 & IS:1554-1, IEC:60228 & IEC:60332-1-2
Application
 Security systems
 Burglar alarm
 Intercom / PA-System
 Cabinet / Panel wiring
 Power limited circuits
 Voice communications / Noisy Environment
 Control/Instrumentation digital signals
 Suitable for low voltage application - Up to 500V system

Price upon request

Multi-Pair Shielded BMS Cable

Specification
  0.50 Sqmm to 1.50 Sqmm (1 Pair to 12 Pair)
Flexible (Class-5) Annealed Bare / Tinned Copper Conductor, HFFR Polypropylene / PVC Insulated , Twisted Pairs laid-up concentrically, Overall shielded (100% Coverage) with Aluminium Mylar tape in contact with Annealed Tinned Copper Drain wire and Overall HR FR-LSH Jacketed Shielded BMS Cables.
Generally as per BS EN 50288-7, IEC:60228 & IEC:60332-1-2
Application
 Security systems
 Burglar alarm
 Intercom / PA-System
 Cabinet / Panel wiring
 Power limited circuits
 Voice communications / Noisy Environment
 Control/Instrumentation digital signals
 Suitable for low voltage application - Up to 500V system

Price upon request

Agilon Cables India Private Limited is a specialized exporter of Building Management & Security System Cables, serving international markets with high-performance cable solutions for smart buildings and infrastructure projects. Our export portfolio includes cables for BMS, fire alarm systems, CCTV networks, access control, intrusion detection, and integrated security systems. Manufactured using high-quality conductors and durable insulation, these cables are designed to ensure signal integrity, safety, and long-term reliability in global installations. All products are produced in accordance with international standards and supplied with export-ready packaging and documentation. Focused exclusively on overseas supply, we support bulk exports and customized specifications for global distributors, system integrators, and project contractors. Choose Agilon Cables India Private Limited for reliable export quality, competitive pricing, and seamless global delivery of building and security system cables.